Most welding faults are not machine faults. If the arc will not strike, check the earth clamp and cables first. If the rod sticks, raise the current a little. Heavy spatter usually means too many amps or a damp rod, and tripping points to a weak supply, overheating or the wrong breaker. Check these before opening the case.

Picture a Tuesday morning in a small workshop. A customer is waiting for a gate, the welder is switched on, the light is green, and the electrode either does nothing or glues itself to the steel. The temptation is to blame the machine, send it to a repairer and lose three days. Very often these faults turn out to be a rusty clamp point, a cable cracked near the plug, a long extension lead or a rod left in the rain.

Our guides to choosing welding rods and to arc versus MIG welding for a rural workshop cover rods and machines. This guide is for the moment something stops working: a symptom-first checklist, the reasons behind each fault, a calculation that shows why long leads cause trouble, and the point at which you should stop and call a technician.

Before you check anything, switch off and unplug. Never touch the electrode holder, the rod or the inside of the machine while it is connected to the supply. Inverter welders can hold a charge after switching off, so internal repair is for a qualified technician, and any mains wiring problem is for a licensed electrician.

Where Do I Start When Nothing Works?

An arc welder is a loop. Current flows from the supply into the machine, out along the electrode cable to the holder, across the arc into the work, and back through the earth clamp and its cable to the machine. Break the loop anywhere and nothing happens. That makes fault-finding simple: follow the loop and test each link in turn.

The welding circuit and where it fails Follow the Loop: Six Places Faults Hide Illustrative, current flows out one cable and back the other 1. Supply and plug Breaker, socket, lead, voltage at the machine 2. Machine Amps dial, fan, vents, fault light, heat 3. Electrode cable Broken strands near plug and holder 4. Holder and rod Worn jaws, damp rod, cracked coating 5. The arc Strike, length, speed, angle and current 6. Work and earth clamp Rust, paint, spring, return cable Test the links in this order: 1, 6, 3, 4, then the settings on 2 and 5
Illustrative diagram of the welding circuit. It carries no measured data; it shows the order in which to check a fault.

Notice the order at the bottom of the figure: supply, then earth clamp, then cables, then holder and rod, and only then the settings. The earth clamp and cables fail far more often than the machine itself, and they are free to check.

Why Will the Arc Not Strike?

Start by asking what the machine is telling you. If there is no power light, the problem is upstream: the breaker, the socket, a loose plug, or an extension lead. If the light is on but there is no arc, the loop is open or the supply to the arc is too weak.

The commonest cause is the earth clamp. A clamp biting on rust, paint, mill scale or galvanising passes almost no current, even though it looks attached. Grind a bright spot on the work, clamp it firmly and try again. If the clamp's spring is weak, replace the clamp, because a clamp that is merely warm to the touch is already losing power as heat.

Next check the cables. Flex them along their length, especially within 30 centimetres of the plug and the holder, where repeated bending breaks the copper strands inside a jacket that looks perfect. A cable with broken strands can pass a small current and fail under load, so the machine seems to work and the arc will not hold. Hot connectors are another clue. Plug the machine in and weld for a few minutes, then feel the lug and the plug with the machine switched off and unplugged. Heat points to a loose joint.

Then look at the rod and the holder. Tap the tip of the electrode on a hard surface to knock off any crust, and if the coating is cracked or soaked, change the rod. A worn holder with burnt jaws that grips poorly will arc inside the holder and not at the rod. Finally, check the dial. A machine set at its minimum current may not strike a 3.2 mm rod, and a machine whose fault light is on needs a rest or a different power source. The light usually means overheating or an out-of-range supply, so read your manual for the code.

Why Does the Electrode Keep Sticking?

A rod sticks when the arc collapses and the tip freezes into the pool. The causes are all ways of starving the arc, so check them in this order.

Likely causeHow to tellWhat to do
Current too low for the rodRod sticks even with a good strike; arc is weak and stutteringRaise the amps in small steps and use the range printed on the rod packet
Poor earth connectionClamp is warm or loose; sticking varies from place to placeGrind a bright spot, clamp firmly, shorten the return lead
Voltage drop in supplyProblem worse at the end of a long extension or on a weak generatorShorten or thicken the supply lead; check generator output under load
Arc too short or too slow to liftRod touches pool when you move inHold a short arc but keep moving; lift the rod a little as you strike
Damp or damaged rodCoating crumbles; spluttering and popsUse dry rods from a sealed pack
Rod too big for the machineMachine cannot sustain the arc at its top settingDrop one rod size

When a rod does freeze to the work, twist it sharply to break it free. If it will not move, release it from the holder and switch off the machine before approaching it. Do not stand holding a stuck electrode, because the rod is live and the metal heats quickly.

How Much Do Long Leads Really Matter?

More than most people think, and the reason is simple Ohm's law. A copper cable has resistance, and resistance multiplied by current is the volts lost along the cable. Voltage lost on the supply side leaves less for the machine, and voltage lost on the welding leads leaves less for the arc, which only has about 20 to 30 volts to start with.

Voltage lost in a 30 metre extension lead at 20 amps Volts Lost in a 30 m Extension Lead Calculated at 20 A, copper cable, by cable size in square mm 14 V 1.5 mm2 8.4 V 2.5 mm2 5.3 V 4 mm2 3.5 V 6 mm2 2.1 V 10 mm2 Out and back is 60 m of copper
Calculated, illustrative: resistivity of copper 0.0175 ohm mm2 per metre, 60 metres of conductor out and back, 20 A. Real cables run hotter and lose slightly more.

A thin lead that loses 14 volts leaves a 230 volt welder with about 216 volts at the machine, and every extra amp the welder draws makes it worse. That is enough to make a machine cut out or an arc stutter, and a thin lead also heats up, which is a fire risk. So plug the welder into a socket close to the work, use the shortest thickest lead you can, and unroll it fully. Our guide to extension cables and electrical safety explains how to choose cable size and what to avoid.

The same rule applies to the welding leads themselves. If the electrode cable and earth cable are long, thin or full of joins, the arc gets less voltage and sticks more. Keep the leads as short as the job allows, and never coil a long lead while welding, because a coil traps heat and a hot lead loses more voltage.

Why Is There So Much Spatter, and Why Does the Arc Wander?

Heavy spatter means the arc is too violent or the rod is not dry. Too high a current is the first suspect: lower it by 10 amps and look again. A rod that has soaked up moisture pops and spits, so replace it. A very long arc scatters metal, so hold the rod closer. Dirty steel with oil, rust or paint adds to it. Our welding rod guide explains rod coatings and current ranges in more detail.

An arc that wanders or blows off to one side, especially near the end of a joint or in a corner, is usually arc blow. Magnetic fields from the current flowing through the work push the arc. Try moving the earth clamp to the other end of the joint or clamping on both sides, split the joint into shorter runs, and keep a short arc. It is a common reason why an experienced welder says the machine feels different on the same job from one day to the next.

Why Does My Welding Machine Keep Tripping?

Work out which device is tripping, because there are three different answers.

What tripsLikely reasonsWhat to do
House breaker, instantlyBreaker too small for the machine's input current, other loads on the circuit, a fault in the wiring or the machineAsk an electrician to check the circuit rating and the machine's input current on its plate
Welder's own cut-out after some minutesDuty cycle exceeded, hot day, blocked vents, dusty fanRest the machine, work in shade, clear vents, weld at a lower current
Welder cuts out or the light flashes at strikeSupply voltage too low or too high, long thin lead, small generatorShorten the lead, test the voltage, raise the generator size, consider a stabilizer rated for the welder's input
Welder runs, then loses output near the end of the dayDust and heat building up inside, fan slowingHave a technician clean and check the machine

Duty cycle is the share of a ten-minute period the machine can weld at a given current before it must rest, and the rating assumes a 40 degree Celsius ambient. In a tin workshop in January the real figure is lower. A thermal cut-out is the machine protecting itself and is not a defect, but if it trips within a few minutes at low current, look for blocked vents or a fan that has failed.

Kenya's grid can swing. Our guide to voltage stabilizers and KPLC fluctuations explains when a stabilizer helps. Any stabilizer used with a welder must be rated for the welder's maximum input current, which is a lot higher than most farm loads, so ask an electrician before connecting one.

When Should I Stop and Call a Technician?

Some faults are not for the workshop floor. Stop welding and have the machine inspected if you see any of these.

Warning signWhy it matters
Burning smell or smoke from the caseOverheated components or insulation breaking down
Tingle or shock from the case or holderInsulation or earthing fault, which can be fatal in wet conditions
Cracked case or sparks insideDamaged internal parts or loose connections
Hot, discoloured or melted plug or socketOverloaded or loose connection, a fire risk
Frayed cable or exposed copperShock and arc hazard
Fault light that returns after restingPersistent overheating or supply problem

The short rains add their own risk. Wet ground, damp gloves and a wet welding table make an electric shock far more dangerous. Weld under cover on dry boards, keep cables off puddles, and wear dry gloves and proper footwear. Our guide to workshop safety and PPE covers the protective kit every welder needs, including a helmet, gloves and clothing that does not catch sparks.

Your Fault-Finding Checklist

StepCheck
1. IsolateMachine switched off and unplugged before touching the holder, clamp or cables
2. SupplyPower light on; breaker and plug fine; lead short and thick enough
3. Earth clampBright metal under the clamp, spring firm, clamp cool after use
4. CablesNo cracks, no broken strands near the ends, connectors tight
5. Rod and holderDry rod, clean tip, holder jaws gripping
6. SettingsCurrent right for the rod size; machine not above its duty cycle
7. EnvironmentVents clear, in shade, dry ground, helmet and gloves on

Where to Find Welding Equipment

Prices change, so we do not print them here. The Fuga price list shows the arc welding machine, welding rods and welding holders we list, with current prices and stock. Check the rating plate of any machine against your power supply before you buy.

Work through the loop in order, starting with the supply, the earth clamp and the cables, and keep rods dry and leads short. If the machine still misbehaves, take the symptom and the rating plate details to a technician. For help choosing a welding machine, WhatsApp 0716 961 018 or visit your nearest Fuga branch, or browse our price list.

Key Takeaways

  • A welder is a loop, so follow it in order: supply, earth clamp, cables, holder and rod, then settings.
  • A rusty or painted earth clamp point is the commonest reason for no arc, and cables break inside their jackets near the plug and holder.
  • A sticking rod usually means too little current, a weak supply, a poor earth or a damp rod.
  • Long thin leads lose volts: a 30 metre, 1.5 square mm extension at 20 amps loses about 14 volts.
  • Check which device trips: the house breaker, the welder's own thermal cut-out or its supply protection each point to different causes.
  • Switch off and unplug before checking anything, keep dry in the rains and call a technician for burning smells, shocks or damaged cases.

Frequently Asked Questions

Why won't my welding machine strike an arc?

The most common reason is a poor earth connection, with the clamp on rust, paint or galvanising. Grind a bright spot, clamp firmly and try again. Then check the cables for broken strands near the plug and holder, make sure the rod is dry and the holder grips it, and confirm that the amps are not set too low.

Why does my electrode keep sticking to the metal?

The arc is collapsing, usually because the current is too low, the earth clamp is poor, the supply voltage is dropping or the rod is damp. Raise the amps in small steps, clean the clamp point, shorten any extension lead and use dry rods. Strike with a quick scratch and lift slightly as the arc starts.

Why is my welder spattering so much?

The usual causes are too high a current, a damp rod, a long arc or dirty, rusty steel. Lower the amps by about 10, hold a shorter arc, use dry rods and grind the joint clean. Spatter that wanders with the arc may be arc blow, which moving the earth clamp can reduce.

Why does my welding machine keep tripping?

It depends on what trips. A house breaker that trips at once may be too small for the machine's input current, and a welder that cuts out after some minutes has probably reached its duty cycle in the heat or has blocked vents. A machine that cuts out at the strike often has a weak supply from a long lead or a small generator.

Is it safe to weld in the rainy season?

Only with care. Wet ground, damp gloves and a wet table make an electric shock much more dangerous. Weld under cover on dry boards, keep cables out of puddles and replace any damaged cable or holder.