A catch-can test shows how much water your sprinklers or rain gun really apply and how evenly. Set out 12 to 20 identical straight-sided cans on a grid, run the system for a timed period in calm air, measure each depth in millimetres, then work out the average rate and a uniformity figure.
Walk a sprinkled plot a few weeks after planting and you can often see the problem without any test. A dark green ring where the sprinkler stands, a yellow stripe between two positions, a dry corner downwind. The farmer waters for an hour and feels sure the crop has had enough, yet part of the plot has had double and part has had half.
The catch-can test turns that feeling into numbers. It costs a handful of tins and half an hour, and it tells you three things: how many millimetres of water you apply per hour, how even the pattern is, and what to change first. Our guide to the tin test for hose sprinklers gives the quick version. This one goes further: grid layouts for sprinklers and rain guns, the arithmetic for uniformity, a worked example, and a list of faults and cures.
Why Does Uniformity Matter More Than the Average?
An average hides the problem. A system can deliver 15 mm an hour on average and still leave a quarter of the field badly short. To make sure the driest part gets enough, you water until it is satisfied, and every other part receives more than it needs. That extra is wasted water, wasted pumping energy, leached fertiliser and, on wet soils, disease.
The arithmetic is simple. If the driest quarter of the plot receives a fraction of the average, you must apply the target depth divided by that fraction to bring it up. A uniformity of 70 percent means you apply about 43 percent more water than the crop needs on average.
Better uniformity is therefore a way of saving water and pumping cost without changing the crop or the pump. It is also the cheapest improvement a sprinkler or rain gun system can get: cans, a notebook and a little arithmetic.
What Do You Need for a Catch-Can Test?
You need identical cans, and the identical part matters. Use straight-sided tins, plastic cups or glasses with the same opening, about 8 to 10 cm across and at least 8 cm deep so water does not splash out. Cans that taper or have different openings give different depths for the same rain, which ruins the comparison.
Collect 12 to 20 cans for a small sprinkler, and more for a rain gun. Add a few stones or pegs to hold them down, a steel measuring tape to space them, a ruler or small measuring jug, a watch or phone timer, a notebook and a pen. A pressure gauge at the sprinkler or gun is worth having, because the test is only meaningful at the pressure you actually run.
How Do You Set Out the Cans?
Set the cans in a square grid across the area that your sprinkler positions water together, not just round one sprinkler, because the overlap is what decides the real pattern. For small sprinklers, space the cans about 2 to 3 metres apart. For a rain gun, which throws much further, space them 3 to 5 metres apart. Irrigation extension guidance suggests a grid of about 3 to 6 metres (10 to 20 feet) on lawns (New Mexico State University), and landscape audit guides suggest runs of 10 to 30 minutes for hose-end sprinklers. These are sensible starting points for a small plot.
Pick a calm time, early in the morning or late afternoon. Wind is a big source of unevenness and it spoils the test if it changes while the cans are out. If it is blowing hard, wait; a strong wind is a bad time to irrigate anyway. Run the sprinkler at its normal working pressure and with the nozzle and arc you normally use. Level each can, tuck it in with a stone, and mark its position on a sketch of the plot.
Do the test in a dry gap in the weather. In the short rains a passing shower will fill the cans and ruin the reading. Put one extra can well away from the sprinklers to catch the rainfall, and subtract it from every reading if you have to test in showery weather.
How Do You Turn the Readings Into Numbers?
Run the system for a measured time, such as 30 minutes for a sprinkler or 45 to 60 minutes for a rain gun, then switch off and measure straight away. If you use a ruler, record the depth in millimetres. If you pour each can into a measuring jug, convert volume to depth with this: depth in millimetres equals volume in millilitres divided by the can opening area in square centimetres, times 10. A can with an 8 cm opening has an area of about 50 cm², so 10 ml of water is about 2 mm.
Here is a worked example from a plot with two overlapping sprinklers, 16 cans in a 4 by 4 grid, run for 30 minutes. The figures are illustrative, chosen to show the calculation.
Step 1: the average depth. Add all 16 readings: 120 mm. Divide by 16: 7.5 mm.
Step 2: the application rate. The average of 7.5 mm fell in 30 minutes, so the rate is 15 mm an hour. One millimetre of water is one litre on every square metre, so this is 15 litres per square metre per hour.
Step 3: the uniformity coefficient. This is the Christiansen coefficient (CU), the standard catch-can index from Christiansen's 1942 work. For each can, find how far it is from the average, ignoring the sign, and add these up. Here the total is 25 mm. CU in percent equals 100 times one minus that total divided by the sum of all readings, so 100 × (1 − 25 ÷ 120) is about 79 percent.
Step 4: the low-quarter figure. Take the driest quarter of the cans, here four cans reading 5, 5, 6 and 6, and average them: 5.5 mm. Divide by the overall average of 7.5 mm to get about 73 percent. The low-quarter figure is the more honest measure of the dry spots and is usually lower than CU, as catch-can research on sprinklers commonly finds.
Step 5: the cost. Suppose the crop needs 10 mm. The driest quarter catches 11 mm an hour, so to give it 10 mm you must run about 55 minutes. In that time the average gets 13.6 mm, about 36 percent more than the crop needed. If you run for 40 minutes to give the average 10 mm, the driest quarter gets only 7.3 mm. Either way, uneven watering is costing you water or yield.
What Is a Good Uniformity Result?
There is no single legal standard, and what counts as good depends on the crop and the system. As a rule of thumb, irrigation guidance from universities and extension services treats a CU of about 80 percent or more as good for sprinkler systems and lower figures as a sign that the pattern needs attention. Some studies of ordinary sprinklers find CU values in the 70s and low 80s in the field. Use these as guidance, not a pass mark, and compare your own result before and after each fix.
| CU result | What it usually means | What to do |
|---|---|---|
| About 85 percent or more | Even, well-set system | Keep the routine; retest each season |
| About 75 to 85 percent | Fair; some dry and wet patches | Fix pressure, nozzle or spacing; retest |
| Below about 70 percent | Poor; obvious stripes or rings | Find the fault in the table below before watering more |
What Does the Pattern Tell You to Fix?
The map of your cans is a diagnosis. Look at where the dry and wet cans fall.
| What the cans show | Likely cause | Fix |
|---|---|---|
| Wet ring far from the sprinkler, dry middle | Pressure too low, jet not breaking up | Raise pressure to the maker's range; check the gauge at the nozzle |
| Wet near the sprinkler, thin edge, fine mist | Pressure too high | Lower pressure; use the correct nozzle |
| One side dry | Wind, tilted riser or an obstruction | Water when calm; set the riser upright and firm |
| Stripes or spokes | Partly blocked or bent nozzle | Clean or replace the nozzle; check the deflector |
| Dry band between positions | Spacing too wide | Move closer; about half to two thirds of the wetted diameter, closer in wind |
| Last sprinklers on the line weaker | Friction loss in the pipe | Larger pipe or shorter laterals; see pipe sizing |
Pressure differences along a line matter. A commonly quoted design rule is that nozzle pressure along a lateral should not vary by more than about 20 percent of the design pressure (Keller and Bliesner), so check the pressure at the first and last sprinkler on a long run. Worn nozzles also grow larger over time, which raises flow and lowers pressure down the line.
What Is Different With a Rain Gun?
A rain gun covers a very large circle from a single point, so a ring of cans around it is not enough. Place the cans on two or three straight lines running outward from the gun, every 3 to 5 metres, as well as across the overlap with the next set position. A gun does not water its circle evenly: most water lands in the middle distance and the outer edge gets a thin ring, which is why overlap is essential. Our rain gun guide covers pressure, wetted radius and overlap.
Run the test for long enough to collect a measurable depth, often 45 to 60 minutes, and if you water part circles to keep the jet off a road or building, test that arc too. A rain gun also puts down water fast, so check the application rate against how quickly your soil absorbs water. If puddles form and run, the rate is too high for the soil even if the pattern is even.
How Often Should You Repeat the Test?
Test once to find your rate and your pattern, again after every change, and then once a season. Test after fitting new nozzles, changing a pump or moving the layout, and any time crops show stripes. Keep the sketches and numbers in a notebook so you can compare year to year.
Then use the result in your routine. Run time equals the depth the crop needs divided by your measured rate, adjusted for the driest part. Our guide to irrigation scheduling shows how to work out the crop's need in millimetres, and our comparison of drip and sprinklers helps if your tests show a sprinkler system is a poor fit for your crop or wind.
Your Catch-Can Checklist
| Step | Check |
|---|---|
| Cans | 12 to 20 identical straight-sided cans, upright and held down |
| Layout | Even grid across the overlap; 2 to 3 m for sprinklers, 3 to 5 m for a rain gun |
| Conditions | Calm air, normal working pressure, no rain |
| Run | Timed: about 30 minutes for sprinklers, 45 to 60 for a rain gun |
| Measure | Depth in millimetres for every can, plotted on a sketch |
| Calculate | Average, rate per hour, CU and low-quarter figure |
| Fix | Pressure, nozzle, riser, spacing, wind, line friction |
| Retest | Repeat after each change and once a season |
Irrigation Equipment to Look At
Prices change, so we do not print them here. See each product page or the Fuga price list for current prices and stock.
| Item | Where it fits |
|---|---|
| Sprinklers | Sprinklers for watering crops and plots; test whichever type you use |
| Zinc Alloy Sprinkler | A zinc alloy sprinkler; see the page for details and test it with the cans |
| Rain Gun (Various Pressures) | Larger fields; match the gun to your pressure and test the overlap |
| Steel measuring tape | Spacing cans and sprinkler positions |
Set out the cans, run the test in calm air, work out your rate and uniformity, and fix the biggest fault first. See our water equipment range and farm equipment, or WhatsApp 0716 961 018 with your sprinkler or rain gun type and your test results and we will help you improve the pattern.
Key Takeaways
- A catch-can test measures how much water your sprinklers or rain gun apply in millimetres an hour and how evenly.
- Use 12 to 20 identical straight-sided cans on an even grid across the overlap, and test in calm, dry air at your normal pressure.
- Average depth divided by run time gives the application rate; one millimetre is one litre per square metre.
- The Christiansen uniformity coefficient (CU) and the low-quarter figure show how even the pattern is.
- Uneven watering costs extra water: at 70 percent low-quarter uniformity you need about 43 percent more to satisfy the driest quarter.
- The pattern points to the fault: pressure, nozzle, riser tilt, spacing, wind or line friction.
- Fix the pattern first, then set the run time from the rate, and retest after every change and once a season.
Frequently Asked Questions
What is a catch-can test for sprinklers?
It is a simple field test: you set identical cans on a grid under the sprinklers, run them for a timed period, then measure the water in each can. The depths show your application rate in millimetres an hour and how evenly the water is spread.
How do I calculate the application rate from my cans?
Add up the depths in all the cans and divide by the number of cans to get the average depth. Divide that by the run time in hours to get millimetres an hour; for example, 7.5 mm in 30 minutes is 15 mm an hour.
What is a good uniformity result for sprinklers?
There is no single standard, but irrigation guidance commonly treats a Christiansen uniformity coefficient of about 80 percent or more as good for sprinklers. Lower figures show dry and wet patches that you should fix before adding more water.
How many cans do I need and how far apart?
Use 12 to 20 identical straight-sided cans in an even grid across the area your sprinklers water together. Space them about 2 to 3 metres apart for small sprinklers and 3 to 5 metres apart for a rain gun.
Can I do the test in windy or rainy weather?
Wind spoils the pattern and the reading, so wait for calm air, early morning or late afternoon. If a shower is possible, put one extra can well away from the sprinklers to measure the rain and subtract it from every reading.