To check an incubator thermometer, compare it with a trusted thermometer in the same place, and for a probe that can go in water also check it in melting ice, where it should read 0 degrees Celsius. To check a hygrometer, run the salt test: a damp salt paste sealed in a closed container with the hygrometer for 8 to 12 hours should make it read about 75 percent. If either instrument is out, write down the error and correct for it, because an instrument that is wrong by a small amount can quietly cost you a whole hatch.
An incubator does not run on the temperature you set. It runs on the temperature its sensor reports, and the sensor can drift, be knocked or simply have been a little off from the factory. The display shows a calm 37.5, the controller is satisfied, and the eggs may be sitting in air that is a degree warmer.
This guide shows how to check and calibrate the thermometer and hygrometer that run your machine, using ice, a second thermometer and a spoonful of salt. It sits beside our guides to incubator humidity control and days 18 to 21 in the incubator, which tell you what the numbers should be. This one tells you whether to believe them.
Why Does a Small Reading Error Cost You Chicks?
Because an embryo is sensitive to temperature over three weeks. Mississippi State University Extension advises that a forced-air incubator be held at 100 degrees Fahrenheit (37.8 degrees Celsius) with total variation kept within 1 degree Fahrenheit, which is about 0.6 degrees Celsius. The same publication says prolonged high or low temperatures reduce hatching success, that high temperatures are the most serious, that consistently high temperatures bring early hatches and consistently cool ones bring late hatches, and that in both cases fewer chicks hatch.
Now see what a faulty thermometer does to that margin. Suppose your display reads 37.5 but the true air temperature at egg level is 38.3, which is 0.8 degrees too warm. You have already used more than the whole allowed swing, and you did it without ever seeing an alarm.
Many machine manuals give a forced-air setting between 37.5 and 37.8 degrees Celsius, and a still-air machine runs warmer at the level of the egg tops. Your manual wins over any article, ours included. The point of calibration is to know that what the manual says is what the eggs actually get.
What Do You Need for the Checks?
Very little, and nearly all of it is already in a Kenyan home.
- A trusted thermometer. A digital clinical thermometer is designed to read accurately in the range of body temperature, which makes it a handy reference near 37 degrees. Avoid broken or old glass mercury thermometers.
- Ice and a clean glass or flask, with clean water.
- Ordinary table salt, a bottle cap or small dish, a little water, and a clean jar or food container with a tight lid or a zip bag.
- Tape, a pen and your hatch record, to write down the correction.
A thermo hygrometer is the instrument most small hatcheries use to watch the inside of the machine, and a spare one is a cheap way to cross-check the first. Keep the spare in a drawer and use it only for checking.
Step 1: How Do You Do an Ice-Point Check on a Thermometer?
The ice point is the simplest fixed temperature there is. Fill a glass to the top with crushed ice, add just enough clean water to fill the gaps, and stir. After a couple of minutes the slush is at 0 degrees Celsius. Put the thermometer's probe or bulb into the middle of the slush, away from the sides and bottom, and wait until the reading stops moving.
A good thermometer reads very close to 0. Note the difference. If it reads 0.5, that thermometer is 0.5 too high at that point, and you should keep that in mind when you read it later.
This check only suits probes and thermometers that can be dipped in water, such as a metal stem or glass thermometer. Do not dunk a thermo hygrometer whose case is not waterproof, and never put a plug-in controller in water. Do not use the boiling point as a check either, because water boils at a lower temperature at higher altitudes, and Kenya has a lot of altitude.
Step 2: How Do You Compare Readings at Incubation Temperature?
Run the incubator empty for several hours until it is steady. Hang or stand your trusted thermometer at egg level, with the bulb at the height of the top of the eggs, and make sure the bulb does not touch the machine or the egg tray. This is the placement that Mississippi State University Extension recommends. Your own display is often fixed in a different place, so a small gap between it and egg level is normal and useful to know.
Wait at least half an hour, then read both without opening the door more than needed. Write down the two numbers, then repeat after a second hour. If the gap is steady, you have a correction. If the gap wanders, the instrument is unreliable and should be replaced.
For a thermometer you cannot place inside, use a warm water bath. Fill a flask with water at about 37 to 38 degrees from a thermos, stir, and put your instrument and the reference thermometer in together. Both should read the same within a few tenths of a degree. Never use hot water, and never put any mains device or controller in the water.
Step 3: How Does the Salt Test Check a Hygrometer?
A saturated salt solution, which means salt with just enough water that some salt stays undissolved, holds the air above it at a fixed humidity. For common table salt (sodium chloride) that humidity is about 75 percent. Published reference tables, drawing on Greenspan's 1977 work at the US National Bureau of Standards, give 75.5 percent at 20 degrees Celsius and 75.3 percent at 25 degrees Celsius.
To run the test:
- Put a level teaspoon or two of salt in a bottle cap or small dish, and add water a few drops at a time until it is a wet paste like damp sand. Some dry grains must remain. If it turns to clear liquid, add more salt.
- Stand the cap in a clean jar or zip bag beside the hygrometer. Keep the salt paste from touching the sensor, and do not let it splash.
- Seal the container and leave it at a steady room temperature, ideally 20 to 25 degrees, out of direct sun and away from drafts, for 8 to 12 hours or overnight.
- Read the hygrometer without opening the seal for longer than needed. It should show about 75 percent.
Keep the whole setup out of the incubator, out of reach of children, and away from machine vents and electrical parts. Salt is harmless to touch, but a salty sensor or a salty fan is not good for a machine.
One caution. The salt test checks one point, 75 percent, while your machine runs at 58 to 65 percent. It is excellent at telling you a hygrometer is badly wrong, and less able to prove that it is perfect. Many low-cost digital hygrometers are specified only to within a few percent, so a reading of 72 or 78 is not alarming, but 60 or 90 is.
What Should You Do If the Readings Are Off?
| Finding | What to do |
|---|---|
| Thermometer within about 0.3 degrees of the reference (our rule of thumb) | Leave it, and log the check |
| Thermometer off by more than that, steady gap | Stick a note on the machine with the correction, and set the machine so that the true temperature, not the display, is right |
| Reading jumps or drifts between checks | Replace the instrument, and use the spare |
| Hygrometer within a few points of 75 in the salt test | Acceptable for incubator use |
| Hygrometer 10 or more points out | Apply the offset, use the calibration function if your model has one, or replace it |
| Two instruments disagree and you cannot tell which is right | Check both against a third, or against the ice and salt references |
An example makes the correction clear. Suppose the salt test makes your hygrometer read 68 percent instead of 75. It reads 7 points low near that range. If the day-to-day display says 52, the true figure may be closer to 59, and the setting should follow the true figure. Because the error may not be the same at every humidity, treat the correction as approximate and re-check it.
Some digital units have a calibration button or a menu to adjust the display, and the manual will say how. If yours does not, write the offset on tape under the display so that anyone using the machine reads it correctly. Do not move the setpoint blindly to compensate. Fix the measurement first, then set the machine.
How Often Should You Check?
Before every hatch, and again after any knock or drop, after a fault that cooked or chilled the machine, and when the hatch results do not match what the readings promised. A set that hatches early, late or with chicks dead in the shell is a prompt to check the instruments before you blame the eggs. Our guide on hatchery record keeping shows how to log each check so you can see drift over time.
Your Calibration Checklist
| Step | Check |
|---|---|
| Ice point | Slush at 0; probe in the middle; note the difference |
| Side by side | Trusted thermometer at egg level, empty machine run for hours, two readings an hour apart |
| Salt test | Damp salt paste, sealed with the hygrometer for 8 to 12 hours, about 75 percent expected |
| Record | Write the correction on tape and in the hatch book |
| Spare | Keep a second thermo hygrometer in a drawer for cross-checks |
| Repeat | Before every hatch and after any knock or fault |
Instruments and Spares to Look At
Prices change, so we do not print them here. See each product page or the Fuga price list for current prices and stock.
| Item | Where it fits |
|---|---|
| Thermo hygrometer | Reading temperature and humidity near the eggs, and a spare for cross-checks |
| Incubator spare parts | Spares to keep with the machine |
Check your thermometer and hygrometer before the next set goes in, write the correction on the machine, and keep a spare. For incubators, thermo hygrometers and spares, see our livestock and poultry equipment, or WhatsApp 0716 961 018 with your machine's make and we will help you find the right instrument.
Key Takeaways
- An incubator runs on the temperature its sensor reports, so a faulty thermometer can ruin a hatch without any alarm.
- A thermometer that can go in water should read 0 degrees Celsius in a slush of crushed ice and clean water.
- Compare your thermometer with a trusted one at egg level in an empty, steady machine, and read both twice an hour apart.
- The salt test: a damp salt paste sealed with the hygrometer for 8 to 12 hours should make it read about 75 percent.
- Write the correction on tape on the machine and in your hatch book, and fix the measurement before you move the setpoint.
- Check before every hatch and after any knock or fault, and keep a spare thermo hygrometer for cross-checks.
Frequently Asked Questions
How do I check if my incubator thermometer is accurate?
Put it in a slush of crushed ice and clean water, where a good thermometer reads 0 degrees Celsius, then compare it with a trusted thermometer at egg level in the running machine. Read both twice, an hour apart, and write down the difference.
How does the salt test for a hygrometer work?
Damp table salt with some undissolved grains holds the air above it at about 75 percent humidity. Seal it with the hygrometer in a closed container for 8 to 12 hours at room temperature, and the hygrometer should read close to 75.
What should I do if my hygrometer reads 68 percent in the salt test?
It is reading about 7 points low near that range. Use the calibration function if your model has one, or write the offset on tape under the display and add it when you read the machine, then re-check later.
Can I check my incubator thermometer in boiling water?
No. Water boils at a lower temperature at higher altitude, so the boiling point is not a reliable reference in much of Kenya. Use the ice point and a side-by-side comparison near 37 degrees instead.
How often should I calibrate my incubator?
Before every hatch, and again after any knock, drop or fault. Also check whenever a hatch comes out early, late or with chicks dead in the shell, because the instruments may be the cause.