When a generator will not start, check in this order: fuel and the fuel tap, oil level, the switch and choke, the air filter, then the spark plug. If it runs but gives no power, check the breaker and the load, then call an electrician. Most faults are fuel, oil, air or spark.

It always happens at the wrong moment. The lights go out, the incubator is cooling, the milk is warming in the tank, you pull the cord ten times and the engine coughs and dies. Panic leads to pulling harder, pouring in more petrol and flooding the engine. A calm walk through the cheapest checks first finds the cause far more often than a spanner does.

Our guide to using a small petrol generator safely on the farm covers placement, fuel storage and connecting to the house, and our generator maintenance guide covers the service schedule that prevents most of these faults. This guide is different: it is a fault-finding order for the day the generator will not start, starts and dies, surges, or runs but gives no power, written so that you can follow it with your eyes, your hands and a little patience.

What Should I Check First When My Generator Will Not Start?

An engine needs four things to run: fuel, air, spark and compression. A small generator that was running last time and will not start now has almost always lost one of the first three. Compression, which is the engine's mechanical health, is rarely the problem unless the engine is old and worn, so leave it for the end.

Begin with the very simple. Is there fuel in the tank, and is it fresh? Is the fuel tap open? Is the engine switch on, and the emergency stop released? Is the choke in the right position for a cold or warm start, as your manual says? These sound too obvious to matter, and they cause more callouts than any other group of faults, because a generator that has not run for weeks sits with fuel that has aged and with switches left in odd positions.

Then listen. An engine that turns over with a healthy pull or a healthy crank but does not fire points to fuel or spark. An engine that will not turn at all, or turns very slowly on the electric starter, points to a battery, a seized part or an engine kept from turning by something else. An engine that fires and dies gives you a different set of suspects, which are covered further down.

Troubleshooting order for a generator that will not start Six Checks, in This Order Illustrative: cheapest and quickest checks first, hands-on checks last 1. Fuel and tap Enough? Fresh? Tap open, cap vent 2. Oil level Level ground Low-oil cut-out 3. Switch and choke On, stop released Choke right for temp 4. Air filter Clogged with dust Clean or replace 5. Spark plug Wet, black, cracked Swap for a new one 6. Carburettor Gummed by old fuel Technician job
Illustrative fault-finding order for a small petrol generator. Work left to right, top row then bottom row, and stop as soon as the set runs.

Could Old Petrol or Dirty Fuel Be the Problem?

Very often, yes. Petrol does not keep indefinitely. After weeks or months in the tank it oxidises and leaves gum and varnish in the small passages of the carburettor, and a set that has stood with old fuel in it often will not start, or starts and then surges and dies. Water and dirt from a dirty or damp container are the other common fuel faults, and the short rains make damp more likely.

Look at the fuel. Fresh petrol is clear and has a sharp smell. Fuel that is dark, cloudy or smells like varnish should be drained into a proper container and replaced. If you can see water or sediment at the bottom of the tank, drain and clean it. Open the fuel tap and look at the fuel line and any filter bowl for blockages. A blocked fuel filter or a kinked line starves the engine, and the symptom is a set that starts and runs for a short time, then dies when the little fuel left in the carburettor is used up.

One easily missed cause is the fuel cap vent. Fuel tank caps have a tiny air vent so that air can replace the petrol that leaves. If the vent is blocked by dust or an old cap, a vacuum builds in the tank and fuel stops flowing. The engine runs for a minute, dies, and restarts after you loosen the cap. If loosening the cap brings the engine back, you have found it.

Do not pour petrol into the carburettor or the air intake to help a start. That is a fire risk and rarely solves the problem. Our petrol generator guide explains storing and handling fuel, and what to do if a set is going to stand unused.

Why Does My Generator Start and Then Die?

A generator that fires and then stops within seconds is telling you something specific. The usual suspects are:

  • A low-oil shutdown. Many small petrol engines have a sensor that stops the engine, or stops it starting, when the oil level is low, to protect the engine. Check the oil on level ground, top up to the mark with the grade in your manual, and try again. A set that is standing on a slope can trigger the cut-out even with enough oil.
  • The choke left on or off. A cold engine needs the choke closed to start and opened as it warms, and a warm engine usually needs little or none. Too much choke floods the engine and it stalls on a rich mixture. Too little, and a cold engine dies as soon as it fires.
  • Fuel starvation. A blocked filter, blocked cap vent or a gummed carburettor lets the engine fire on the fuel left in the bowl and then run out.
  • A dirty air filter. A filter clogged with dust chokes the engine so it fires and dies or runs roughly. January and February dust makes this common.
  • An overload on start-up. A set that is asked to start with a heavy load already connected can stall. Switch off everything connected and start the engine first, then add loads one at a time.

Why Does My Generator Surge or Hunt?

Surging, or hunting, is when the engine speed rises and falls in a steady rhythm, and the lights and motors it powers pulse with it. The engine speed is held by a governor, and when the engine is not getting a steady supply of fuel and air, the governor chases it up and down.

The most common causes are the same fuel faults: stale petrol, a partly gummed carburettor, a blocked cap vent or an air leak into the intake. Surging also appears when the choke is left partly closed, when the air filter is dirty, or when the load is unstable. A welder, a compressor or a motor that cycles on and off makes any generator work harder. Our guide to surge watts and motor starting explains why a motor asks for several times its running power at the start, and the same logic applies to a generator.

Try the simple fixes first: fresh fuel, a clean air filter, the cap loosened, the choke fully open once warm, and a lighter load. If the surging continues, a carburettor clean or governor adjustment is a technician's job, because over-speeding a generator damages what it powers.

Why Does It Run but Give No Power?

If the engine runs smoothly but sockets are dead, the problem is on the electrical side, which is the alternator, its voltage regulator and the circuit breaker. Start with what you can see safely. Is the generator's own breaker or switch on, or has it tripped? Reset it once, with everything disconnected, and see if power returns. A breaker that trips again straight away is telling you there is a fault or an overload.

Overload is the most common cause of a tripped breaker. Add up what is connected and compare it to the set's rating on the nameplate, remembering that motors need a surge of power to start. The same sizing logic for running a welder on a generator shows how a small machine can ask for far more power than its label suggests.

If the breaker is on, nothing is overloaded and there is still no output, or the output voltage is too low or too high, the fault is inside the alternator or its voltage regulation, often called the AVR. Possibilities include a failed AVR, worn brushes or a failed capacitor, depending on the type of generator. Do not open the electrical side of a running generator, and do not probe wires. This is a job for a licensed electrician or a generator technician. If the lights burn very bright or flicker wildly, switch the set off and keep sensitive equipment disconnected, because over-voltage can destroy a fridge or an incubator controller.

Never connect a generator to a wall socket to feed the house. A lead with a plug on both ends can push power back out onto the Kenya Power line and endanger linesmen working on it. If you want the generator to supply the house wiring, a licensed electrician must fit a changeover switch. Plug appliances directly into the generator, or through a correctly rated outdoor extension lead.

What About Electric Start and Diesel Generators?

An electric-start set adds a battery and a starter, and they fail in a predictable way. A set that clicks but will not crank, or turns over very slowly, usually has a flat battery or corroded terminals. Check that the terminals are clean and tight, charge the battery, and use the pull cord as a backup if the set has one. Our generator maintenance guide explains why standby batteries are the largest single cause of no-start callouts.

A diesel set has no spark plug, so the checks change. After it runs out of fuel, air gets into the fuel system and the engine will not start until it has been bled as the manual describes. A blocked fuel filter, water in the diesel, a flat battery and a faulty stop solenoid are other common causes. Diesel generators also should not be run for long with no load, which is covered in the maintenance guide above. Diesel work beyond filling the tank, checking the oil and changing a filter is best done by a technician.

Quick Fault-Finding Table

What you see or hearMost likely causeWhat to checkWho fixes it
Will not fire, no smell of fuelNo fuel, tap closed or stop switch onTank, tap, engine switchYou
Turns over, will not fireOld fuel, wet or fouled plug, flooded engineFuel quality, plug, chokeYou, then a technician
Starts then dies within secondsLow oil cut-out, blocked cap vent, blocked filterOil level, cap loosened, fuel flowYou
Rises and falls in speedGummed carburettor, stale fuel, air leakFresh fuel, air filter, loadTechnician if it continues
Runs, no power at the socketsTripped breaker or overload, failed AVRBreaker, load, nameplate ratingElectrician
Clicks, will not crankFlat battery or corroded terminalsBattery, terminals, chargeYou, then a technician
Hard to start in the dry seasonDirty air filterFilter clogged with dustYou
First three checks for each generator symptom Start Where the Symptom Points Illustrative: first checks by symptom, cheapest first Will not start Fuel and tap, switch and choke, spark plug Starts then dies Oil level, cap vent, air filter Surges or hunts Fresh fuel, air filter, steady lighter load Runs, no power Breaker, overload, then an electrician
Illustrative map of where to look first for each symptom. It is a starting point, not a diagnosis, and it applies to small petrol sets.

What Can I Check Safely, and When Do I Stop?

You can safely check the fuel, the oil level, the switches, the choke position, the air filter and the plug, with the engine off and cool. Before touching anything, switch the engine off, let it cool, and disconnect every appliance from the set. Never run a generator indoors, in a store, a garage, a poultry house or a shed. Petrol engines make carbon monoxide, a gas you cannot see or smell, and it builds up fast in enclosed spaces. Our safe-use guide gives placement distances and the rest of the rules.

Always let the engine cool before refuelling. Petrol spilled on a hot exhaust can ignite. Use a funnel, wipe up spills, and keep smoking and flames well away. Follow the manual and your electrician on earthing the set rather than improvising with a wire and a stake. Never remove covers or touch wiring while the engine runs.

Stop and call a technician if the engine will not start after the fuel, oil, air filter and plug checks, if a breaker keeps tripping with nothing connected, if the voltage is wrong, if you smell burning, or if the set makes knocking, grinding or squealing sounds. Pulling a cord fifty times on a flooded or mechanically damaged engine only adds to the bill.

The Generators We List

Fuga lists Generators under machinery. The product page gives branch availability and the warranty terms but no technical specification, so ask the team on WhatsApp for the model, the rated output, whether it has electric start and the manual before you buy or when you troubleshoot. A minimum one-year warranty applies on machines bought from us. Prices change, so we do not print them here; see the product page or the Fuga price list.

Next time your generator will not start, check the fuel, oil, switches, filter and plug in that order, write down what you find, and call us with the notes in your hand. Most generator faults are old fuel, a low oil level, a blocked vent, a dirty filter or a tripped breaker, and all of them can be found before dark.

Key Takeaways

  • A generator needs fuel, air and spark: check fuel and the tap, oil level, switch and choke, air filter and spark plug, in that order.
  • Old petrol, a blocked fuel cap vent and a low-oil cut-out are common reasons a set starts and then dies.
  • Surging usually points to stale fuel, a gummed carburettor, a dirty air filter or an unsteady load.
  • If it runs but gives no power, check the breaker and the load first, then call an electrician for the AVR or alternator.
  • Never run a generator indoors, never refuel a hot engine, and never connect it to a wall socket without a changeover switch fitted by a licensed electrician.
  • Stop and call a technician for knocking noises, burning smells, wrong voltage or a breaker that trips with nothing connected.

Frequently Asked Questions

Why will my petrol generator not start?

The most common causes are old or contaminated petrol, no fuel or a closed fuel tap, a low oil level triggering the cut-out, the choke in the wrong position, a dirty air filter and a wet or fouled spark plug. Check them in that order, cheapest first.

Why does my generator start and then die?

It is usually low oil tripping the cut-out, a blocked fuel cap vent, a blocked fuel filter, a gummed carburettor, a dirty air filter or too much choke. Check the oil on level ground, loosen the fuel cap and try again with fresh fuel.

Why does my generator surge up and down?

Surging means the governor is chasing an uneven supply of fuel and air. Stale petrol, a partly blocked carburettor, a dirty air filter or a load that keeps changing are the usual causes. Try fresh fuel and a lighter, steady load, and call a technician if it continues.

My generator runs but there is no power at the sockets. What is wrong?

Check whether the set's breaker has tripped and reduce the load. If the breaker is on and nothing is overloaded, the fault is likely in the alternator or its voltage regulator, which is a job for a licensed electrician or generator technician.

Can I plug my generator into a wall socket to power the house?

No. A lead with a plug on both ends can push power back onto the Kenya Power line and endanger linesmen. Plug appliances straight into the generator, or have a licensed electrician fit a changeover switch if you want it to feed the house wiring.